Safety Precautions, Maintenance & Recommended Use

PoE safety

  • Use at least shielded CAT5e or better ISO/IEC 11801 and EN 50288 certified Ethernet cables allowed for PoE use and with strong EMI shielding.

  • The maximum length of PoE is up to 100 m and depends strongly on the cable and PoE injector used. Qumea does not accept any liability for functional limitations, interference or damage caused by cables that are too long or of incorrect type.

  • If the PoE cable is damaged (for example, the inner cord is exposed or broken) or the plug loosens, stop using it immediately. Continued use may lead to electric shocks or fire.

  • Do not touch the PoE cable with wet hands. Doing so may lead to short circuits, malfunctions, or electric shocks.

  • Only use certified PoE power sourcing devices (injector, router, switch, etc.). Using an uncertified, unapproved or incompatible PoE power source or other supply may cause fire, explosion or other hazards. QUMEA takes no liability for improper or unfit user infrastructure.

Accessory Safety

  • Use only accessories approved for use with this sensor model by QUMEA. The use of any other types of accessories may void the warranty, may violate local regulations and laws, and may be dangerous. Contact the manufacturer or your retailer for information about the availability of approved accessories in your area.

Device Safety

  • Maximum Permissible Exposure (MPE) warning: Ensure that at least 31 cm separation distance is maintained between the QUMEA RADIQ-1 sensor and any human body

  • Do not use this unit’s Ethernet plug for connecting anything else than the intended PoE supply cable.

  • Ensure the device is mounted firmly prior to use.

  • Ensure the device is not covered and has enough ventilation.

Specific precautions for EMC

  • QUMEA RADIQ-1 series sensor equipment is compliant with Class A of EN 55032. In a residential environment this equipment may cause radio interference.

  • QUMEA sensor products are tested to the requirements of EN 55032 (Emissions) and EN 55035 (Immunity). There are no specific precautions which must be taken in order to comply with the requirements of Directive 2014/30/EU Essential Requirements in Section 1 of Annex I.

  • In addition, QUMEA sensor products are tested to ensure spurious emissions are within the specified limits, as well as meeting the requirements for adaptivity, which mitigates against problems caused by co-location with other wireless products.